The World's Finest Water Activated Batteries

Home Up Model 313

 Model 312
 

 

News
Products
Design
Location
Terms & Conditions

The MAGNEVOLT Model 312 battery is a single section unit containing 10 cells.

The battery operates under a load of 59.9 ohms at approximately 0.25 amps for 6 hours.

CONDITIONS:
Battery Temp: (Deg F)

32

104

Electrolyte Temp: (Deg F)

32

104

Electrolyte Salinity: (%)

1.5

3.6

Constant Load: (ohms)

59.9

59.9

PERFORMANCE:
Mean Voltage:

14.9

15.3

Voltage Range:

15.4-13.5

15.7-13.5

Discharge Time: (hours)

6.5

6

Mean Current: (amps)

0.248

0.256

Capacity: (amp-hr)

1.67

1.58

Energy: (watt-hours)

24.9

24.2

Energy Density:

(watt-hour/cubic inch):

2.53

2.47

(watt-hour/pound inch):

48

46.7

PHYSICAL CHARACTERISTICS
Dry Weight: (oz)

8.3

Height: (in)

3.38

Width: (in)

2.25

Thickness: (in)

1.3

Volume (cubic inch):

9.8

TYPICAL ENVIRONMENTAL
Shock

100 g's for 7 milliseconds

Vertical:

100 G for 11 msec, 3 impacts

Transverse:

50 G for 11 msec, one impact

Vibration:

90 min at 0.04 in amplitude

traversing 10 to 55 cps in one minute

30 min at 10 G amplitude traversing 55 to 500 cps in 15 min.

Temperature:

Operating 32 to 104 deg F

Storage Temperature:

-65 to 160 deg F

Humidity Exposure:

90 days at 90% R.H. at 90 deg F