| PERFORMANCE: |
Main |
Timer |
|
Main |
Timer |
|
|
|
|
|
Power |
Cell |
|
Power |
Cell |
|
|
|
|
|
Section |
|
|
Section |
|
|
|
|
|
| Constant Load: (ohms) |
14.6 |
11.1 |
|
14.6 |
11.1 |
|
|
|
|
| Activation |
|
|
|
|
|
|
|
|
|
| Seconds to 10.0 volts |
45 |
x |
|
30 |
x |
|
|
|
|
| Seconds to 11 volts |
180 |
x |
|
90 |
x |
|
|
|
|
| Average Voltage: |
11.8 |
1.5 |
|
12.2 |
1.5 |
|
|
|
|
| Voltage Regulation |
11.6 |
1.45-1.52 |
|
11.75 |
1.51-1.55 |
|
|
|
|
| Discharge Time (min): |
500 |
480 |
|
490 |
480 |
|
|
|
|
| Capacity: (amp-hr) |
6.7 |
0.14 |
|
6.8 |
0.14 |
|
|
|
|
| Power (whr): |
9.5 |
0.21 |
|
10.2 |
0.21 |
|
|
|
|
| Whr/lb (based on wt in air): |
60 |
|
|
|
|
|
|
|
|
| Whr/cubic inch: |
4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| PHYSICAL CHARACTERISTICS |
|
|
|
|
|
|
|
|
|
| Weight in Air: (oz) |
21 |
|
|
|
|
|
|
|
|
| Weight in Seawater (oz): |
12 |
|
|
|
|
|
|
|
|
| Minimun Tube I.D. to Contain |
4 |
|
|
|
|
|
|
|
|
| Number of Cells |
|
|
|
|
|
|
|
|
|
|
Main Power Section: |
8 |
|
|
|
|
|
|
|
|
|
Timer Cell: |
1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| TYPICAL ENVIRONMENTAL |
|
|
|
|
|
|
|
|
|
| Shock |
|
|
|
|
|
100 g's for 11 millseconds |
|
|
|
| Vibration: |
|
|
|
|
|
10 g's, 55 to 500 cps, |
|
|
|
|
|
|
|
|
|
0.04 in amplitude 10 to 55 cps |
|
|
|
| Temperature: |
|
|
|
|
|
-55 to +71 deg F for 90 days |
|
|
|
| Humidity Exposure: |
|
|
|
|
|
90% R.H. at 90 deg F. for 90 days |
|
|
|
| Alititude: |
|
|
|
|
|
35,000 ft. |
|
|
|
| Storage: |
|
|
|
|
|
7 years in dry sealed container |
|
|
|