| CONDITIONS: |
|
|
|
|
|
|
|
| Battery Temp: (Deg F) |
35 |
85 |
|
|
|
|
|
| Electrolyte Temp: (Deg F) |
35 |
85 |
|
|
|
|
|
| Electrolyte Salinity: (%) |
3.5 |
3.5 |
|
|
|
|
|
| Constant Load: (ohms) |
0.478 |
0.478 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| PERFORMANCE: |
|
|
|
|
|
|
|
| Activation: (seconds to 9.5
volts) |
5 |
2 |
|
|
|
|
|
| Average Voltage: |
10.9 |
11.3 |
|
|
|
|
|
| Regulation Voltage |
10 |
11.1 |
|
|
|
|
|
| Discharge Time (min): |
18 |
17 |
|
|
|
|
|
| Capacity: (amp-min) |
410 |
400 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| PHYSICAL CHARACTERISTICS |
|
|
|
|
|
|
|
| Weight in air: (lb) |
2 |
|
|
|
|
|
|
| Height: (in) |
6.85 |
|
|
|
|
|
|
| Diameter: (in) |
2.75 |
|
|
|
|
|
|
| Number of Cells |
8 |
|
|
|
|
|
|
| Packing: |
|
|
Mil-P-116 Meth IId |
|
|
|
|
|
|
|
|
|
|
|
|
| TYPICAL ENVIRONMENTAL |
|
|
|
|
|
|
|
| Temperature: |
|
|
Operating and non operating 30 to 130 deg F |
|
|
|
|
| Storage: |
|
|
5 years at average temp 90 Deg F or below |
|
|
|
|
| Operating Depth: |
|
|
3 to 1200 ft. |
|
|
|
|